Power Shower
Site Requirements - Electrical
The pump must be permanently connected to the
electricity supply via a double pole isolating switch with
a minimum contact gap of 3mm in both poles. The switch must
be readily accessible but out of reach of a person using a
fixed bath or shower, except for the cord of a pull cord operated
switch. The wiring must be connected to the switch without
the use of a plug or socket outlet. The supply cable selected
for installation must conform to the relevant table in the
I.E.E. regulations. To enhance electrical safety a 30mA RCD
(Residual Current Device) should be installed in all UK electric
and pumped shower circuits. This may be part of the consumer
unit or a separate unit.
This Installation Must Be
Earthed
Site Requirements - Water
To ensure correct operation the pump must be connected
to a cistern fed supply of hot and cold water at nominally
equal pressures. The pump must never be connected to the mains
cold water supply. The cold water cistern must always be above
the pump to ensure priming of the unit (see diagrams for details).
The hot water storage cylinder and cold water cistern should
each have a minimum storage capacity of 114 litres in order
to ensure adequate infill rate. If supplying a number of outlets,
it is recommended that the cold water cistern should have
a minimum capacity of 230 litres in order to ensure adequate
infill rate. Both hot and cold water supplies to the pump
must be dedicated and separate from any other outlets or connections.
Water Connections
Mixer Valve Inlet Connections:
- 15mm compression fittings on hot and cold inlets
- Rising, falling and rear entry water supplies via swivel
inlet elbows
- Distance between centres of inlet elbows: Minimum 146mm
Maximum 160mm
- Integral check valves prevent back flow into hot and cold
water supplies
Mixer Valve Outlet Connections:
- Threaded 1/2" BSP top and bottom (one blanked)
- The mixer valve is supplied with an adaptor which provides
either 15mm compression or 1/2" BSP for the hose fitting.
Minimum 146mm Maximum 160mm
- Integral check valves prevent back flow into hot and cold
water supplies
Mixer Valve Outlet Connections:
- Threaded 1/2" BSP top and bottom (one blanked)
- The mixer valve is supplied with an adaptor which provides
either 15mm compression or 1/2" BSP for the hose fitting.
Pump Water Connections:
- 4 flexible connectors with 15mm push-in fittings
Pump Motor Specification
- Twin impeller pump
- Rating - 50Hz, 240V, 590W, single phase, recommended duty
cycle 15 minutes on, 45 minutes off
- Automatic resetting thermal overload cut-out
- Flow Rate : up to 16 litres per minute
- Pressure : Maximum pressure at maximum flow 1.2 bar equivalent
to a 12.6m head of water
- Variable speed control : 100% to 50% of performance
Materials of Construction
Mixer Valve Brass inlet elbows and body, ABS trim,
engineering polymers for thermostat cartridge.
Pump WRC approved materials which are inherently
limescale resistant.
Dimensions (mm) |
|
Height |
Width |
Depth |
Power Shower Packs : |
Flush Fit Valve |
165 |
165 |
64 |
|
Surface Mount Valve |
110 |
218 |
126 |
|
Pump |
141 |
242 |
97 |
Product Approval
Designed to comply with Water Fitting Bye-Laws
Scheme operated by The Water Research Centre
Power Shower Packs and AS2000T only: thermostatic
performance designed to conform to British Standards
Designed to comply with the latest product electrical
safety standards
Company Approval
Triton is registered by The British Standards
Institute and all Triton products are designed, tested and
manufactured under Quality Management Systems certified to
BS EN ISO 9001 : 1994 and Environmental Management Systems
approved to ISO 14001.
Guarantee
All in one power showers and power shower pack
pumps are covered by a 12 month guarantee (power shower pack
mixer valve has 3 year guarantee) from the date of purchase.
For a small premium this can be extended to 3 to 5 years (for
full details please see the warranty application form included
in every Triton shower pack).
Installation
Installation should be carried out by competent
tradesmen in accordance with the detailed fitting instructions
(supplied with every unit) and Water Regulations and Bye-Laws.
A copy of the fitting instructions is available on request
from the Customer Service Department if it would help when
planning your installation.
Trade Installer Hotline
Trade installers can phone a dedicated hotline
on 024 7632 5491 for immediate technical advice on
installation, and to ensure product suitability for commercial
and multiple installations.
|