Return
to Technical Index - Return
to HRC Fuses
ASTA Certified to BS 88: Part 2 1988. Comply with IEC 269
Parts 1 & 2.
Tested to 80kA at 415V AC.
|
Amp
Range
|
Fixing
Centres
(mm)
|
BS 88
Ref.
|
TLC
-
MEM
|
GEC
-
LAWSON
|
BRUSH
-
HAWKER
|
BUSSMANN
-
DORMAN
|
|
__2 - _32
|
44.5
|
A1
|
SA2
|
NIT
|
2F21
|
NITD
|
|
__2
- _32
|
73
|
A2
|
SB3
|
TIA
|
2H07
|
AA0
|
_35 - _63
|
73
|
A3
|
SB4
|
TIS
|
K07
|
BAO
|
_80 - 100
|
73
|
-
|
SO
|
OS
|
K07R
|
OSD
|
_80 - 100
|
94
|
A4
|
SD5
|
TCP
|
L14
|
CEO
|
125 - 200
|
94
|
-
|
SD6
|
TFP
|
M14
|
DEO
|
ASTA Certified to BS 88: Part 2 1988. Comply with IEC 269
Parts 1 & 2.
Tested to 80kA at 415V AC.
|
Amp
Range
|
Fixing
Centres
(mm)
|
BS 88
Ref.
|
TLC
-
MEM
|
GEC
-
LAWSON
|
BRUSH
-
HAWKER
|
BUSSMANN
-
DORMAN
|
|
_80 - 100
|
111
|
B1
|
SF5
|
TC
|
L09
|
CD
|
|
125 - 200
|
111
|
B2
|
SF6
|
TF
|
M09
|
DD
|
250 - 315
|
111
|
B3
|
SF7
|
TKF
|
N09
|
ED
|
250 - 315
|
133
|
-
|
SG7
|
TKM
|
N11
|
EFS
|
355 - 400
|
111
|
B4
|
SF8
|
TMF
|
P09
|
ED
|
ASTA Certified to BS 88: Part 6 1988. Ref. F1
Tested to 80kA at 415V AC.
This range of HRC fuselinks has staggered contacts and is
for use in industrial and general applications. Special motor
rated fuselinks are listed
|
Amp
Range
|
Length
x
Dia (mm)
|
TLC
-
MEM
|
GEC
-
LAWSON
|
BRUSH
-
HAWKER
|
BUSSMANN
-
DORMAN
|
|
2 - 32
|
60 x 14
|
SN2
|
NS
|
F06
|
NSD
|
|
ASTA Certified to BS 88: Part 6 1988. Ref. F1
Tested to 80kA at 415V AC.
This range of HRC fuselinks has staggered contacts and is
for use in industrial and general applications. Special motor
rated fuselinks are listed
|
Amp
Range
|
Length
x
Dia (mm)
|
TLC
-
MEM
|
GEC
-
LAWSON
|
BRUSH
-
HAWKER
|
BUSSMANN
-
DORMAN
|
|
16 - 63
|
68 x 17
|
SP
|
ES
|
GO5
|
ESD
|
|
ASTA Certified to BS 88: Part 6:
1988
Breaking Capacity of 16kA at 240V AC.This range of
fuselinks is available for general lighting and heating.
|
Amp
Range
|
Length
x
Dia (mm)
|
TLC
-
MEM
|
GEC
-
LAWSON
|
BRUSH
-
HAWKER
|
BUSSMANN
-
DORMAN
|
|
2 - 25
|
51 x 14
|
SS
|
SS
|
D04
|
SSD
|
|
Breaking capacity 33kA at 415V AC to BS 1361: 1971
These HRC cartridge fuselinks are for use in house service
cut-outs by Electricity Companies in the UK and by Supply
Authorities elsewhere.
They also comply fully with the dimensional power-loss, fusing
factor, discrimination and time-current characteristic requirements
of BS 1361: 1971. Fusing factors do not exceed 1.5. ASTA certified
in accordance with BS 1361 Type IIa and IIb. Time-current
characteristic curves available on request.
|
Amps
|
Length
x
Dia (mm)
|
TLC
-
MEM
|
GEC
-
LAWSON
|
BRUSH
-
HAWKER
|
BUSSMANN
-
DORMAN
|
|
15
|
57 x 22.23
|
154R
|
RHF
|
KR85
|
RHD
|
|
20
|
204R
|
30
|
304R
|
40
|
404R
|
45
|
454R
|
50
|
504R
|
60
|
604R
|
80
|
804R
|
100
|
1004R
|
ASTA Certified to BS 1361: 1971: Type 1
Category 240AC16.
These ferrule cap fuselinks are for use in domestic installations
for lighting and heating circuits. All, except List No. 1505LC
and 1510LC, have been type tested and ASTA certified in accordance
with BS 1361: 1971: Type 1.
Category of Duty 240AC16. List No. 1505LC and 1510LC which
are non standard ratings in the 15A barrel have been type
tested to BS 88: 1967 and are colour coded black.
|
Amps
|
Length
x
Dia (mm)
|
Colour |
TLC
-
WYLEX
|
GEC
-
LAWSON
|
MEM
|
BUSSMANN
-
DORMAN
|
|
_5
|
23 x _6.35
|
White
|
CFL_5
|
D55
|
5LC
|
DSD5
|
|
15
|
26 x 10.32
|
Blue
|
CFL15
|
D1515
|
15LC
|
DSD15
|
20
|
26 x 10.32
|
Yellow
|
CFL20
|
D1520
|
20LC
|
DSD20
|
30
|
29 x 12.70
|
Red
|
CFL30
|
D3030
|
30LC
|
DSD30
|
45
|
35 x 16.67
|
Green
|
CFL45
|
D4545
|
45LCS
|
DSD45
|
Return to Top
|